Available Particles and Energy Levels
Particle Type | Energy Range | Beam Current | Beam Size | Uniformity |
---|---|---|---|---|
Protons | 30-70 MeV | 1 nA - 750 μA | 5 cm × 5 cm | ±4% |
Deuterons | 15-35 MeV | 1 nA - 50 μA | 5 cm × 5 cm | ±5% |
Alpha Particles | 30-70 MeV | 0.1 nA - 50 μA | 5 cm × 5 cm | ±7% |
Heavy Ions | 1-55 MeV/nucleon | 0.01 nA - 1 nA | 2 cm × 2 cm | ±3% |
Test Cell and Control Room Layouts

Test Cell A
- Dimensions: 4m × 3m × 3m
- Door dimensions: 2.5m × 2.5m
- Shielding: 2m concrete walls
- Access: Direct beam line from cyclotron

Test Cell B
- Dimensions: 4m × 3m × 3m
- Door dimensions: 2.5m × 2.5m
- Shielding: 2m concrete walls
- Access: Secondary beam line

Control Room
- Dimensions: 6m × 4m × 3m
- Monitoring stations: 4 positions
- Safety systems: Redundant monitoring
- Connectivity to test cells
Connectivity Between Test Cell and Control Room
Fiber Optic Network
- Redundant single-mode and multi-mode fiber connections
- Real-time data transmission
- Video monitoring capability
- Emergency communication systems
Empty Conduit with Pull Rope
- Additional cable routing
- Customer-specific connections
- Future expansion capability
- Easy maintenance access
Power Distribution
- UPS backup systems
- Emergency power shutdown
- Customer power outlets
- Ground fault protection
Dosimetry and Radiological Survey Procedures
Real-time Dosimetry
- Ionization chambers
- Silicon diode detectors
- Continuous monitoring
- Automated dose control
Area Monitoring
- Radiation detectors throughout facility
- Alarm systems
- Access control
- Emergency shutdown capability
Personnel Safety
- TLD badges
- Electronic dosimeters
- Safety training programs
- Emergency procedures
Radioactive Material Shipping/Receiving Policies
Shipping Requirements
- Proper DOT packaging and labeling
- Radiation transport index limits
- Advance notification required
- Security screening procedures
Receiving Procedures
- Incoming radiation survey
- Contamination monitoring
- Secure storage protocols
- Chain of custody documentation
Storage Specifications
- Storage size: 2m × 2m × 2m per cell
- Security: 24/7 monitoring
- Access control: Biometric locks
- Environmental controls: Temperature/humidity
PE and Borated PE Shielding Block Availability
Polyethylene Blocks
- Standard sizes: 10cm × 10cm × 10cm
- Custom sizes available
- Easy handling and positioning
- Neutron attenuation capability
Borated Polyethylene
- Enhanced neutron shielding
- Various boron concentrations
- Custom fabrication available
- Long-term stability
Lead Shielding
- Gamma ray attenuation
- Various thicknesses
- Modular design
- Easy assembly/disassembly
Media and Scientific Papers Generated at Facility
Recent Publications
- "Radiation Effects Testing for Commercial Space Applications" - IEEE Transactions on Nuclear Science, 2025
- "Single Event Effects in Modern Space Electronics" - Radiation Effects and Defects in Solids, 2025
- "Proton Testing Protocols for CubeSat Missions" - Small Satellite Conference, 2025
Industry Presentations
- Space Radiation Effects Conference 2025
- IEEE Nuclear and Space Radiation Effects Conference
- Commercial Space Radiation Testing Workshop
Technical Reports
- Facility Capability Assessment
- Safety and Compliance Documentation
- Customer Test Reports (confidential)
Technical Documentation Downloads
Custom Requirements
Need specifications not covered here? Our engineering team can provide detailed information for your specific testing requirements.